S. R. Lab InstrumentsS. R. Lab Instruments

Quick Search

Home About Us What We Offer Media Gallery Contact Us Enquiry

What We Offer

Showcase Showroom

play now

{short description of image}Cooling Equipment
Share: FacebookTwitterStumble

We Manufacturers and Exporters a wide range of Scientific, Laboratory, Testing, Cooling Equipments & Chambers that is manufactured using quality SS, CRCA, MS, HSS, CS, to ensure high quality & durability & refrigeration system to cater the needs of cooling as well as Ultra Cooling requirements. These are further quality tested on well-defined parameters before being supplied to our clients.

Ice Flakers

Ice Flakers

Our range of ice flaker is known to  produces crushed ice, slow melting ice flakes &are mainly used in the growing fields of medical, industrial,chemical industries,hospitals, colleges, institutions, r & d & q. C. Laboratories.

 

construction:


s. S bin of 304 quality for collection of ice & the outer is made of crca non-contiminant expoxy powder coated, it rests on heavy angular frame structure.

 

refrigeration system:


efficient coling system with hermetically sealed compressors & cfc free refrigerant, complete with air cooled condensor & fan motor. It is a self-contained ice producer with a well insulated ice storage bin of various capacities.

 

working:


it is a direct drive mechanism system which delivers ice flakes faster. Insulated bin keeps the ice for longer period. A door is provided on the top of the bin for easy removal of ice. There is a auto cut off system, when the bin is full of ice it cuts off the refrigeration systems & re-starts when the level comes down.


optional:


additional safety thermostat for controller. It can be supplied with water filler & water failure protection device, the system will get cut off when the water supply fails & get started automatically when the water supply is resumed.


also available

 

  • qmp models / complete s. S unit.
  • viscometric bath (low temp)

Send Enquiry

Stability Chamber

Stability Chamber

We robustly construct our range of stability chamber.The exterior is made of AISI S.S304 interior is made of AISI S.S 316 with PUF/Glasswool insulation.

Offered in various specifications, these are appreciated across the globe.

 

  • Air circulation:
  • Forced air circulation to ensure uniform temp.
  • Heating & humidification:
  • SS air heaters are provided for heating above ambient
  • temperatures. ASS water boiler with reservoir & float valve
  • produces steam for humidifying the chamber.
  • Refrigeration System:
  • A hermetically seated compressor
  • with CFC Free refrigerant
  • provides temperatures eeltoront conditions.
  • Temp. Control:
  • A Solid State Temp, control with panels housing all the controls &
  • PT-100 Sensors are used as wet & dry bulbs

 

Safety Features:

 

  • Built-in temp, deviation, audio/ visual alarms
  • Safety thermostat for over shooting of temp. Safety circuit to cut off the whole systems in case of malfunction. (Only applicable to
  • Microprocessor based models). HRC fuses for compressor heaters & mains

Send Enquiry

Laminar Flow


Laminar Flow

The srl make laminar air flow cabinet provides a class 100 air flow in the work area for operations where products is of utmost importance. The unrestricted open front work area allows the use of equipment under biologically clean conditions.

Applications:
The laminar air flow cabinet is designed to provide a high degree of protection for process products in laboratories and production facilities. Many critical applications in the medical, pharmaceutical, nuclear-power, and micro electronic fields demand an ultra-clean work environment which is free from biological and particulate contamination.

Operation:
ambient air is drawn in through pre-filter and is introduced in the work zone through the hepa the average velocity in the work zone is maintained between 0. 4 and 0. 5 m/s. Air cleanliness th e work zone is better than class 3. 5 (100) in accordance-fed std 209 e

Constructions:
The cabinets are fabricated out of thick board duly sunmica clad or mild steel cabinet duly epo coated. The work table is made of thick board which is sunmica clad at top or s. S table top w be provided as optional accessories. All joints are sealed with silastic sealant. Side panels are provided of thick transparent acrylic sheets. The unit is fitted with pre-filter and is made to pass through highly effective hepa (high efficiency particular air) filter having efficiency rating ah hi as 99. 997% with hot, dop, thus retaining all air-borne particles of size : 0. 3 micron and larger. Using a dynamic machine, the blower and motor assembly is statically and dynamically balanced. Blowers are mounted on vibration isolation mounts to minimize vibration. The working is illuminated by flourescent lightings fitted to the unit. Height of the working table provides comfortable "sit down" working position for the operation to work on 220/230 volts ac. Supply

Specification:

  • Air velocity - between 0. 4 to 0. 5 m/s +-20%

  • Hepa efficiency - 99. 997% at 0. 3 microns with dop test

  • Pre-filter - washable with an arrestance up to 90 % microns

  • Sound level - less than 65 db (a)

  • Light intensity - lux 900 - 1300 lux

  • Cleanliness federal - standard 209 e class 100

  • Power supply - 220 v single phase 50 hz


Optional:

  • S. S table top.

  • U. V lights attachment

  • Front acrylic door

  • Gas / vacuum cock

  • Castor wheels at the bottom


Technical specification

Vertical laminar flow

Horizontal laminar flow

model

size in ft

model

size in ft

vl-2a

2 x 2

h l-2a

2 x 2

vl-3b

3 x 2

h l- 3b

3 x 2

vl-4c

4 x 2

h l - 4 c

4 x 2

Send Enquiry

DE-Humidifier

DE-Humidifier

These equipments are capable of maintaining Relative Humidity of 35% RH to 45% RH & are mainly used in pharmaceutical laboratories, capsules, strip packing, tablet section, packing rooms, processing industries, printing & lithography, photographic industries, communication equipment rooms, computer & data storage various other purposes. The equipment is based on refrigeration principle. It removes the moisture content of humid air in an enclosed room & condenses the moisture of the humid air into water, which continuously drops into a tray. No chemicals or dehydrating substances are used, Relative Humidity can be maintained depending upon the cubic feet volume, the temp. & no of occupants in the room, the walls & ceilings should be vapour proof to minimize infiltration of moisture into the room. It is also connected with a humidification system which increases the humidity in case there is low Humidity & maintains automatically

 

Construction :

 

Heavy gauge construction of CRCA sheet or AISI Stainless Steel. Robust angular structure removable casing panels makes all parts easily accessible for adjustments & service when required Working of the Environment Controller (De-humidifier Cum Humidifier)


Refrigeration System :


It is fitted with a hermetically sealed compressors to operate on 230 volts +/-5% A. C,Single phase 50Hz, with heat exchanging coil, water condensing coil & fan motor assembly. The unit is mounted on a trolley with a water collection tank at the bottom. Humidification system has boiler tank with boiler heater, S.S water reservoir tank with float valve is provided to create humidity in case of low humidity.


Dimensions


  • Horizontal Model overall Size : 30"H x 18"W x 18"D Vertical
  • Model overall Size : 42"H x 22"W x 24"D

 

Application :


The following are the required conditions for Installation of Environmental controller (De-Humidifier).


CAPACITY ROOM VOLUME NO OF OCCUPANTS IN THE ROOM

 

  • 1.0 tonne 2500 cu.ft 5
  • 1.5 tonnes 3750 cu.ft 7
  • 2.0 tonnes 5000 cu.ft 9


Room Temperature :


When operating the equipment the room temp, will tend to rise on account of its moisture removal latent heat load & the electrical motor operating in the equipment, A sufficient capacity Air Conditioner given below to be installed along with the Environmental Controller (De-Humidifier) The total heat load thus added to the room is given under. Environmental Controller Approx. Heat Load added to Air Condition


(De-Humidifiers) Capacity the room.


  • 1 tonne 2500 BTU 1 tonne
  • 1.5 tonnes 9000 BTU. 1.5 tonnes
  • 2 tonnes 12000 BTU 2 tonnes.

 

RH conditions :

 

A few of the typical temperature & the corresponding Relative Humidity conditions attainable in a room are given here under. Room Temp, is maintained at RH of the room (approx) 70C F or higher 45% 74C F or higher 40% 81C F or higher 45% Duo to contlnuos development & improvements in design, we reserve the tight to change the specification without notice.

 

Send Enquiry

Humidity / Stability Test Chamber


Humidity / Stability Test Chamber

Environmental test chamber

Temp Range: 10 °C above ambient to 60 °C / 10 °C to 60 °C / -10°C to 60°C,

Accuracy: ± 0.2° C

Humidity Range: 40% to 98% RH

Accuracy: ± 3% R.H

 

Application:

These equipments are used for climatic & durability tests of electrical & electronic components, corrosion test on mechanical assemblies, tests on packages, paints & varnishes, cement plants, apparatus & materials for simulated tropical & extreme tropical conditions & for botanical & zoological investigations, testing of chemicals, drugs, pharmaceutical, cosmetics, medicine, capsules etc.

 

Construction:

Double walled, the exterior is made of CRCA with non-contaminant epoxy powder coated & interior is made of AISI S.S 304 with PUF/Glasswool insulation , double walled door with PUF/Glasswool insulation. For Stability Chamber interior is made of S.S 316 & Exterior is made of S.S 304 (as per GMP Model)

 

Air Circulation:

Forced air circulation to ensure uniform temp.

 

Heating & Humidification:

Air heaters are provided for heating above ambient temperatures. A water boiler with reservoir & float valve produces steam for humidifying the chamber.

 

Refrigeration System:

A hermetically seated compressor with CFC Free refrigerant provides temperatures eeltoront conditions.

 

Temp. Control:

A Solid State Temp, control with panels housing all the controls & PT-100 Sensors are used as wet & dry bulbs.

 

Optional

Model Available as per GMP / complete S. S unit & direct Temp.& RH% readout . strip chart recorder. Microprocessor based

PID temp. Control with printer interface (Centronic Port). PC interface with RS232CPC / RS-485 interface for multiple networking of controller. µP Profile Controller for Ramp / soak for cyclic applications chamber illumination with flourescent or U. V lamps.

 

Validation:

DQ, IQ. OO & PQ Protocols with complete documentation & certification traceable to National & International Standards.

 

Safety Features:

Built-in temp, deviation, audio/ visual alarms.

Safety thermostat for over shooting of temp. Safety circuit to cut off the whole systems in case of malfunction. (Only applicable to Microprocessor based models). HRC fuses for compressor heaters & mains.

 

Special Care:

Suitable K.V.A. Servo Controlled Voltage Stabilizer is strongly recommended.

 

 

TECHNICAL SPECIFICATION

Model

Internal Dimension (cms)

Rating

HC/SC-A

45 x45x45

1.5 K.W

HC/SC-B

45x45 x71

1.5 K.W

HC/SC-C

70 x 70 x 55

2.5 K.W

HC/SC-D

100x 100x 100

3.0 K.W

HC/SC-E

230 x 110 x 110

4.0 K.W

Send Enquiry

De-Humidifier Cum Humidifier


De-Humidifier Cum Humidifier

Item Code: vertical-horizontal.

Humidity Range : 35% RH Accuracy : +/-3% RH

 

These equipments are capable of maintaining relative humidity of 35% RH to 45°% RH & are mainly used in pharmaceutical laboratories, capsules, strip packing, tablet section, packing rooms, processing industries, printing & lithography, photographic industries, communication equipment rooms, computer & data storage various other purposes.

 

Construction :

Heavy gauge construction of CRCA sheet or AISI Stainless Steel. Robust angular structure, removable casing panels makes all parts easily accessible for adjustments & service when required

 

Working of the Environment Controller (De-humidifier Cum Humidifier)

The equipment is based on refrigeration principle. It removes the moisture content of humid air in an enclosed room & condenses the moisture of the humid air into water, which continuously drops into a tray. No chemicals or dehydrating substances are used, Relative Humidity can be maintained depending upon the cubic feet volume, the temp. & no of occupants in the room, the walls & ceilings should be vapour proof to minimize infiltration of moisture into the room. It is also connected with a humidification system which increases the humidity in case there is low Humidity & maintains automatically.

 

Refrigeration System :

It is fitted with a hermetically sealed compressors to operate on 230 volts +/-5% A. C,Single phase 50Hz, with heat exchanging coil, water condensing coil & fan motor assembly. The unit is mounted on a trolley with a water collection tank at the bottom. Humidification system has boiler tank with boiler heater, S.S water reservoir tank with float valve is provided to create humidity in case of low humidity.

 

Dimensions

Horizontal Model overall Size : 30"H x 18"W x 18"D

Vertical Model overall Size : 42"H x 22"W x 24"D

 

Application :

The following are the required conditions for Installation of Environmental controller (De-Humidifier).

 

CAPACITY

ROOM VOLUME

NO OF OCCUPANTS IN THE ROOM

1.0 tonne

1.5 tonnes

2.0 tonnes

2500 cu.ft

3750 cu.ft

5000 cu.ft

5

7

9

 

Room Temperature :

When operating the equipment the room temp. will tend to rise on account of its moisture removal latent heat load & the electrical motor operating in the equipment, A sufficient capacity Air Conditioner given below to be installed along with the Environmental Controller (De-Humidifier) The total heat load thus added to the room is given under.

Environmental Controller

(De-Humidifiers) Capacity

Approx. Heat Load added to the room.

Air Condition

1 tonne

1. 5 tonnes

2 tonnes

2500 BTU

9000 BTU.

12000 BTU

1 tonne

1.5 tonnes

2 tonnes.

 

Send Enquiry

Humidity Chamber (Environment Test  Chamber)

Humidity Chamber (Environment Test Chamber)

Our humidity chamber environment test equipments are used for climatic & durability tests of electrical & electronic components, corrosion test on mechanical assemblies, tests on packages, paints & varnishes, cement plants, apparatus & materials for simulated tropical & extreme tropical conditions & for botanical & zoological investigations, testing of chemicals, drugs, pharmaceutical, cosmetics, medicine, capsules etc.


ENVIRONMENTAL TEST CHAMBER


  • Temp Range: 10 °C above ambient to 60 °C / 10 °C to 60 °C / - 10°C to 60°C,
  • Accuracy: ± 0.2° C
  • Humidity Range: 40% to 98% RH
  • Accuracy: ± 3% R.H

 

Construction:


Double walled, the exterior is made of CRCA with noncontaminant epoxy powder coated & interior is made of AISI S.S 304 with PUF/Glasswool insulation , double walled door with PUF/Glasswool insulation. For Stability Chamber interior is made of S.S 316 & Exterior is made of S.S 304 (as per GMP Model)

 

Air Circulation:


Forced air circulation to ensure uniform temp. Heating & Humidification: Air heaters are provided for heating above ambient temperatures. A water boiler with reservoir & float valve produces steam for humidifying the chamber.


Refrigeration System:


A hermetically seated compressor with CFC Free refrigerant provides temperatures eeltoront conditions.


Temp. Control:


A Solid State Temp, control with panels housing all the controls & PT-100 Sensors are used as wet & dry bulbs. Optional Model Available as per GMP / complete S. S unit & direct Temp.& RH% readout . strip chart recorder. Microprocessor based PID temp. Control with printer interface (Centronic Port). PC interface with RS232CPC / RS-485 interface for multiple networking of controller. μP Profile Controller for Ramp / soak for cyclic applications chamber illumination with flourescent or U. V lamps.


Validation:


DQ, IQ. OO & PQ Protocols with complete documentation & certification traceable to National & International Standards.

 

Safety Features:


Built-in temp, deviation, audio/ visual alarms. Safety thermostat for over shooting of temp. Safety circuit to cut off the whole systems in case of malfunction. (Only applicable to Microprocessor based models). HRC fuses for compressor heaters & mains.


Special Care:


Suitable K.V.A. Servo Controlled Voltage Stabilizer is strongly recommended.

 

Send Enquiry

B. O. D Incubator


B. O. D Incubator

Application :

Used for incubator of large number of samples in hospitals research institutions, public health laboratories, etc these chambers can be used for environment testing of production samples. They are suitable for storage of electronic components, biological specimen & accelerated ageing tests of large number of pharmaceutical samples They can also be used for botanical, cytological & plant where controlled conditions of temp., illumination are required.

 

Air Circulation :

Efficient forced air circulating system is provided to ensure uniform conditions inside the Chamber.

Optional :

Models available as per GMP/Complete S.S unit, Strip chart recorder.Microprocessor based PID temp. control with printer interface, RS 232 CPC/ RS 485 interface for multiple networking of controller.

Validation Protocols :

IQ, OQ, PQ & DQ Protocols with complete documentation & certification traceable to National & International Standards.

Safety Features :

Built-in temp. deviation audio/visual alarm. Safety thermostat for over shoot temp. cut off, safety circuit to cut off the whole system in case of malfunction (Only applicable in microprocessor based models).

Special Care :

A suitable K. V. A Servo Controlled Voltage Stabilizer is strongly recommended in case of voltage fluctuations.

TECHNICAL SPECIFICATION

BACTERIOLOGICAL INCUBATOR (THERMOSTATICALLY CONTROLLED

Model

BI-A

BI-B

BI-C

BI-D

BI-E

Capacity Ltrs

45

90

120

215

325

Chamber Size (cms)

35 x 35 x 35

45 x 45 x 45

45 x 45 x 60

60 x 60 x 60

60 x 60 x 90

Cap (Watts)

120

250

400

500

800

 

BACTERIOLOGICAL INCUBATOR (STERILIZING)

Model

BI-A

BI-B

BI-C

BI-D

BI-E

Capacity Ltrs

45

90

120

215

325

Chamber Size (cms)

35 x 35 x 35

45 x 45 x 45

45 x 45 x 60

60 x 60 x 60

60 x 60 x90

Cap (Watts)

120

250

400

500

800

Send Enquiry

Ice Flaker


Ice Flaker

Application:

These equipment produces crushed ice, slow melting ice flakes &are mainly used in the growing fields of medical, industrial, chemical industries,hospitals, colleges, institutions, r & d & q. C. Laboratories.

Construction:

S. S bin of 304 quality for collection of ice & the outer is made of crca non-contiminant expoxy powder coated, it rests on heavy angular frame structure.

Refrigeration system:

Efficient coling system with hermetically sealed compressors & cfc free refrigerant, complete with air cooled condensor & fan motor. It is a self-contained ice producer with a well insulated ice storage bin of various capacities.

Working:

It is a direct drive mechanism system which delivers ice flakes faster. Insulated bin keeps the ice for longer period. A door is provided on the top of the bin for easy removal of ice. There is a auto cut off system, when the bin is full of ice it cuts off the refrigeration systems & re-starts when the level comes down.

Optional:


Additional safety thermostat for controller. It can be supplied with water filler & water failure protection device, the system will get cut off when the water supply fails & get started automatically when the water supply is resumed. Also available gmp models / complete s. S unit.

Special care :

A suitable k. V. A servo controlled voltage stabilizer is recommended

Technical specification

model

capacity in hours

capacity of bin in kgs

external dimensions

w x d x h

if-a.

50 kg / 24 hours

40 kg. Approx

24. 00x24. 00x38. 98 (610x610x990)

if-b.

60 kg / 24 hours

40 kg. Approx

24. 00x24. 00x38. 98 (610x610x990)

if-c.

70 kg / 24 hours

50 kg. Approx

24. 00x25. 98x38. 98 (610x660x990)

if-d.

90 kg / 24 hours

60 kg. Approx

36. 22x24. 00x38. 98 (920x610x990)

if-e.

100 kg / 24 hours

80 kg. Approx

36. 22x24. 00x38. 98 (920x610x990)

if-f.

200 kg / 24 hours

160 kg. Approx

36. 22x24. 00x38. 98 (920x610x990)

if-g.

400 kg / 24 hours

320 kg. Approx

53. 15 x29. 92x42. 13 (1350x760x 1070)


Send Enquiry

Cold Chamber / Ultra Low Temp. Cabinet

Cold Chamber / Ultra Low Temp. Cabinet

Item Code: vertical-horizontal

Temp. Range : -20°c / -35 0c / -40 0c / -80 0c

Application:cold chamber (ultra low temperature)

Equipment specially designed & suitable for electronic industry, space programs research, research labs, defence labs, blood banks, biological specimens, serum,vaccines,research laboratories medical specimens, clinical samples, industrial research etc, for testing under extreme low temp. Conditions.

Construction :


fabricated on heavy angular structure, triple walled chamber, two chamber of aisi s. S 304. The exterior chamber from crca sheet duly powder coated with puf insulation.

circulation

forced air circulation to ensure uniform temp.

Door :

Double door for vertical models only first one of 6 mm acrylic & the second one of metal with two walls & puf insulation.

Refrigeration systems :

Single stage compressor for temp. Up to-20 0c / -35 0c & double stage compressors for temp. Up to - 40°c / -80 0c with cascade systems, oil separators, high pressure cutoff, low pressure cutoff, electrical accessories etc. Cfc free refrigerants of suva - 95 for second stage & r- 134 for the first stage will be used.

Temp. Control :

Digital temp. Control with 24 hrs timer.

Optional :-

Micro processor based pid temp. Control with pc interface & strip chart recorder. Gmp model / complete s s unit .

Safety measures :

Built-in temp. Deviation audio/visual alarm. Safety thermostat for over shoot temp. Cut off safety circuit to cut off the whole system in case of malfunction (only applicable in microprocessor based models). Hrc fuses for compressor heaters & mains, time delay circuit for safety of compressor etc. Circuit breakers for over & under temp. Conditions.

Special attention :

must be kept in a a. C room & suitable rating servo controlled voltage stabilizer is recommended.

Technical specifications

Vertical model

Model

Capacity (ltrs)

Internal dimensions

ulvf-a

45 ltrs

35 x 35 x 35 (cms)

ulvf-b

90 ltrs

45 x 45 x 45 (cms)

ulvf-c

170 ltrs

50 x 40 x 85 (cms)

ulvf-d

265 ltrs

57 x 57 x 88 (cms)

ulvf-d

425 ltrs

70 x 65 x 95 (cms)

ulvf-d

650 ltrs

80 x 80 x 105 (cms)

Send Enquiry

Contact Us
Mr. Sati A. M. (Proprietor)
No. G-16, M. K. Industrial Premises CO. OP. Society Ltd., Sonawala Cross Road No. 2, Goregaon (East)
Mumbai, Maharashtra - 400 063, India
Telephone:  +(91)-(22)-26858753/ 26856124

Contact via E-mail

Contact via Mobile

Contact via SMS

Home  |  About Us  |  What We Offer  |  Media Gallery   |  Site Map  |  Contact Us  |  Enquiry

Member IndiaMART.com © S. R. Lab Instruments, All Rights Reserved. (Terms of Use)